待辦事項 #37820

ttmacro.exe hanging when using the 'connect' command

啟用日期: 2017-12-16 02:54 最後更新: 2023-01-10 08:44

回報者:
負責人:
(無)
類型:
狀態:
開啟
元件:
里程碑:
(無)
優先權:
5 - 中
嚴重程度:
7
處理結果:
檔案:
Vote
Score: 0
No votes
0.0% (0/0)
0.0% (0/0)

細節

Using a Windows 7 Intel machine and the following code causes ttmacro.exe to hang at the 'connect' command every now and then. In each hanging case, the macro is started in a Tera Term window that is open and connected to a COM port. When the macro is mid-hang, the macro window shows the command being executed is 'connect COMPort'. I am able to communicate with desired COM in the Tera Term window (such as send and receive data over the COM) as if the connect command completed successfully, but the next command (closesbox) does not execute.

The behavior is similar to the macro being disconnected from the Tera Term window and becoming unresponsive.

NEW_COM="COM2"
do while 1
    strcompare NEW_COM "COM5"
    if result == 0 then
        NEW_COM="COM6"
    else
        NEW_COM="COM5"
    endif
    ; Disconnect from current host/COM port
    gethostname hostname
    dispstr '[MACRO:Disconnecting from 'hostname']'
    disconnect 0
    ; random pause necessary to give Tera Term time to think.
    pause 1

    ; figure out the command line format from the given COMx format
    i=0
    maxCOMs=32
    while i<=maxCOMs
        sprintf 'COM%d' i
        strcompare NEW_COM inputstr
        if result = 0 then
            ; Found the correct COM port, put the command line arguments together
            sprintf2 COMPort '/C=%d /timeout=5' i
            break
        else
            i = i + 1
        endif
    endwhile

    ; If we never found the correct COM port, error out/user intervention
    if i>maxCOMs then
        sprintf2 msg 'Could not correlate given COM port to a command line format: %s\n' NEW_COM
        strconcat msg 'Please make sure the Manufacturing Test Team is aware of this error occuring"\n'
        strconcat msg 'In the mean time, connect manually by going to "Setup -> Serial port..."\n'
        strconcat msg 'Press "OK" when complete'
        strspecial msg
        messagebox msg 'Invalid COM Port'
        gethostname hostname
        dispstr '[MACRO:User connected to 'hostname']'
        exit
    endif

    sprintf2 msg 'Connecting to new port with argument(s): %s\n' COMPort
    strconcat msg 'If this window stays open long enough for you to read this,\n'
    strconcat msg 'then select File -> Disconnect and follow the next pop-up window instructions.'
    strspecial msg
    statusbox msg "Connecting to new COM"
    connect COMPort
    closesbox
    if result = 2 then
        dispstr '[MACRO:Connected to 'NEW_COM']'
    elseif result = 1 then
        sprintf2 msg 'Could not automatically connect to %s\n' NEW_COM
        strconcat msg 'Please connect manually by going to "Setup -> Serial port..."\n'
        strconcat msg 'Press "OK" when complete'
        strspecial msg
        messagebox msg 'Connection Problem'
        gethostname hostname
        dispstr '[MACRO:User connected to 'hostname']'
    endif
    ; random pause necessary to give Tera Term time to think.
    mpause 20
    clearscreen 0
endwhile

Ticket History (2/2 Histories)

2017-12-16 02:54 Updated by: ryan_holleran
  • New Ticket "ttmacro.exe hanging when using the 'connect' command" created
2023-01-10 08:44 Updated by: nmaya
  • 優先權 Update from 7 to 5 - 中
  • Details Updated

Attachment File List

No attachments

編輯

You are not logged in. I you are not logged in, your comment will be treated as an anonymous post. » 登入